PXW5,PXW7,PXW9型號已淘汰,對應的替代產品為PXR5,PXR7,PXR9。
PXR系列溫控器簡介:
◆雙排顯示PV、SV等數(shù)據(jù);
◆帶手/自動模式,切換便利;
◆ 8段斜坡/保溫程序(選件)
◆滿量程0.5%精度,85-256V AC 50/60HZ供電工作。
◆ 再傳輸輸出功能DC4-20ma和RS485通訊功能(選件)
◆遙控輸入功能(選件)
◆數(shù)字量輸入最多2點(選件):通過一點高品質開關量ON/OFF,可改變設定值SV,控制動作起/停,斜坡/保溫控制的開始/ 復位,自動調節(jié)功能的起/停,報警鎖存的復位、定時器計時開始;
◆二路輸出(選件):用于加熱/冷卻控制
◆ 加熱斷線報警(選件)
◆自帶一路報警功能:最多3點(選件)。
富士溫控表PXR4/5/7/9系列選型說明
數(shù)字位
|
規(guī)格
面板尺寸W×H
|
代號
|
4
|
5
|
6
|
7
|
8
|
-
|
9
|
10
|
11
|
12
|
13
|
4
|
48×48mm
|
4
|
|
|
|
|
|
|
|
|
|
|
48×96mm
|
5
|
|
|
|
|
|
|
|
|
|
|
72×72mm
|
7
|
|
|
|
|
|
|
|
|
|
|
96×96mm
|
9
|
|
|
|
|
|
|
|
|
|
|
5
|
輸入信號
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T
|
|
|
|
|
|
|
|
|
|
|
|
R
|
|
|
|
|
|
|
|
|
|
RTD/Pt100歐姆(℃)
|
|
N
|
|
|
|
|
|
|
|
|
|
RTD/Pt100歐姆(℉。)
|
|
S
|
|
|
|
|
|
|
|
|
|
1~5V DC
|
|
A
|
|
|
|
|
|
|
|
|
|
4~20mA DC
|
|
B
|
|
|
|
|
|
|
|
|
|
6
|
控制輸出1
|
|
|
|
|
|
|
|
|
|
|
|
繼電器接點輸出
|
|
|
A
|
|
|
|
|
|
|
|
|
SSR/SSC驅動輸出
|
|
|
C
|
|
|
|
|
|
|
|
|
4~20mA DC輸出 注1
|
|
|
E
|
|
|
|
|
|
|
|
|
7
|
控制輸出2
|
|
|
|
|
|
|
|
|
|
|
|
無
|
|
|
|
Y
|
|
|
|
|
|
|
|
繼電器接點輸出
|
|
|
|
A
|
|
|
|
|
|
|
|
SSR/SSC驅動輸出
|
|
|
|
C
|
|
|
|
|
|
|
|
4~20mA DC輸出
|
|
|
|
E
|
|
|
|
|
|
|
|
再傳輸輸出(4~20mA DC)
|
|
|
|
R
|
|
|
|
|
|
|
|
8
|
版本號
|
|
|
|
|
1
|
-
|
|
|
|
|
|
9.
|
附加功能1
|
|
|
|
|
|
|
|
|
|
|
|
無報警
|
|
|
|
|
|
|
0
|
|
|
|
|
1個報警
|
|
|
|
|
|
|
8
|
|
|
|
|
加熱器斷路報警 注2
|
|
|
|
|
|
|
2
|
|
|
|
|
1個報警+加熱器斷路報警 注2
|
|
|
|
|
|
|
3
|
|
|
|
|
8段斜坡/保溫程序
|
|
|
|
|
|
|
4
|
|
|
|
|
1個報警+8段斜坡/保溫程序
|
|
|
|
|
|
|
5
|
|
|
|
|
加熱器斷路報警+8段斜坡/保溫程序 注2
|
|
|
|
|
|
|
6
|
|
|
|
|
1個報警+加熱斷路報警+8段斜坡/保溫程序 注2
|
|
|
|
|
|
|
7
|
|
|
|
|
兩個報警
|
|
|
|
|
|
|
F
|
|
|
|
|
兩個報警+8段斜坡/保溫
|
|
|
|
|
|
|
G
|
|
|
|
|
兩個報警+加熱器斷路報警+8段斜坡/保溫 注2
|
|
|
|
|
|
|
H
|
|
|
|
|
3個報警
|
|
|
|
|
|
|
M
|
|
|
|
|
遙控設定 注2
|
|
|
|
|
|
|
D
|
|
|
|
|
遙控設定+2個報警 注2
|
|
|
|
|
|
|
P
|
|
|
|
|
10
|
操作說明書 電源電壓
|
|
|
|
|
|
|
|
|
|
|
|
中文 100~240VAC
|
|
|
|
|
|
|
|
W
|
|
|
|
日文 100~240VAC
|
|
|
|
|
|
|
|
Y
|
|
|
|
英文 100~240VAC
|
|
|
|
|
|
|
|
V
|
|
|
|
無 24VAC/24DC
|
|
|
|
|
|
|
|
C
|
|
|
|
日文 24VAC/24DC
|
|
|
|
|
|
|
|
A
|
|
|
|
英文 24VAC/24DC
|
|
|
|
|
|
|
|
B
|
|
|
|
11
12
13
|
附加功能2
|
|
|
|
|
|
|
|
|
|
|
|
無
|
|
|
|
|
|
|
|
|
0
|
0
|
0
|
RS485(Modbus)通訊
|
|
|
|
|
|
|
|
|
M
|
0
|
0
|
RS485(Z-ASC11) 通訊
|
|
|
|
|
|
|
|
|
N
|
0
|
0
|
1點數(shù)字輸入
|
|
|
|
|
|
|
|
|
S
|
0
|
0
|
2點數(shù)字輸入 注3
|
|
|
|
|
|
|
|
|
T
|
0
|
0
|
RS485(Modbus) 通訊+1點數(shù)字輸入
|
|
|
|
|
|
|
|
|
V
|
0
|
0
|
RS485(Z-ASC11) 通訊+1點數(shù)字輸入
|
|
|
|
|
|
|
|
|
W
|
0
|
0
|
注1:輸出4-20mA不能與加熱器斷路報警一起選。(即選項9中的2、3、6、7、H)
|
注3:若選擇2點數(shù)字輸入,輸出2或加熱器斷路報警不能選。
|
注2:不能與RS485+1點數(shù)字輸入一起選。(即選項11、12、13中的V00)
|
|